Type some words to find content.
eg: fuse, arrestor, 00110115 technical, MCCB...
Recent searches
Tehnical support
This email address is being protected from spambots. You need JavaScript enabled to view it.
Filter type
Clear all
Expand all
Open all
Connection
5
4
2
Function
1
16
3
1
16
Mounting type
16
4
19
16
Size
5
6
3
3
3
Tightening torque (Nm)
4
10
1
Utilization category
2
14
Voltage type
2
14
Program type

NH fuse-switch disconnectors and fuse bases

Items: 0
001690915
KVL-B-000 3p F50 Bottom
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
80
Rated short-time withstand current Icw at 1s (kA):
5
Altitude (m):
≤ 2000
001690916
KVL-B-000 3p F50 Top
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
80
Rated short-time withstand current Icw at 1s (kA):
5
Altitude (m):
≤ 2000
001690910
KVL-B-00 3p M8-M8
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
160
Rated short-time withstand current Icw at 1s (kA):
5
Altitude (m):
≤ 2000
001690911
KVL-B-00 3p BC95-BC95
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
160
Rated short-time withstand current Icw at 1s (kA):
5
Altitude (m):
≤ 2000
001690912
KVL-B-1 3p M10-M10
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
250
Rated short-time withstand current Icw at 1s (kA):
8,6
Altitude (m):
≤ 2000
001690913
KVL-B-2 3p M10-M10
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
400
Rated short-time withstand current Icw at 1s (kA):
15
Altitude (m):
≤ 2000
001690914
KVL-B-3 3p M10-M10
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
630
Rated short-time withstand current Icw at 1s (kA):
15
Altitude (m):
≤ 2000
001690920
KVL-B/FT-00 3p M8-M8
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
160
Rated short-time withstand current Icw at 1s (kA):
5
Altitude (m):
≤ 2000
001690922
KVL-B/FT-1 3p M10-M10
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
250
Rated short-time withstand current Icw at 1s (kA):
8,6
Altitude (m):
≤ 2000
001690923
KVL-B/FT-2 3p M10-M10 TOP
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
400
Rated short-time withstand current Icw at 1s (kA):
15
Altitude (m):
≤ 2000
001690924
KVL-B/FT-2 3p M10-M10 BOTTOM
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
400
Rated short-time withstand current Icw at 1s (kA):
15
Altitude (m):
≤ 2000
001690926
KVL-B/FT-3 3p M10-M10
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
630
Rated short-time withstand current Icw at 1s (kA):
15
Altitude (m):
≤ 2000
001690930
KVL-B/SF-00 1p M8-M8
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
160
Rated short-time withstand current Icw at 1s (kA):
5
Altitude (m):
≤ 2000
001690931
KVL-B/CF-00 1p M8-M8
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
160
Rated short-time withstand current Icw at 1s (kA):
5
Altitude (m):
≤ 2000
001690932
KVL-B/SF-1 1p M10-M10
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
250
Rated short-time withstand current Icw at 1s (kA):
8,6
Altitude (m):
≤ 2000
001690933
KVL-B/SF-3 1p M10-M10
Class name:
Fuse switch disconnector
Rated operational current Ie AC-21 A/B at 690V (A):
630
Rated short-time withstand current Icw at 1s (kA):
15
Altitude (m):
≤ 2000
001691071
PRS KVL-000 3p TOP
Class name:
Protection cover
001691072
PRS KVL-000 3p BOTTOM
Class name:
Protection cover
001691073
UGS KVL-000 3p/34-39
Class name:
Protection cover
001691074
BLAL KVL-000 lateral
Class name:
Cover support
>
>
0
Your basket is empty.
/images/video/NY2025/Greetings_en-GB.pngen-GB